Page 304

Catalogue_WEB_WoP_Jun16

Pricing and Online Ordering at www.alphalabs.co.uk 302 Haemostasis Routine Screening Reagents The APTT reagent in the kit contains phospholipids and silica to ensure a highly consistent and stable product. The APTT reagent is lupus anticoagulant insensitive. Lupus anticoagulant insensitive reagents yield more reliable factor assay results than reagents that are sensitive to lupus inhibitors. Prolonged clotting times may be observed in the following situations: deficiency of intrinsic coagulation factors, presence of heparin, in liver diseases, vitamin K Deficiency or other anticoagulants that affect the intrinsic pathway. n Liquid, ready to use reagents n Open-vial stability: 30 days if stored at 2-8C n Expected range: 27-42 secs TEClot TT n freephone order 0800 387732 n buy online at www.alphalabs.co.uk TEClot PT-S The one stage Prothrombin Time measures the clotting time of test plasma after the addition of Thromboplastin reagent containing calcium chloride. The reagent supplies a source of “tissue thromboplastin”, activating Factor VII, and is therefore sensitive to all Stage II and III Factors. Deficiencies of Stage I Factors (VIII, IX, XI, and XII) are not detected by the test. PT-S reagent contains an extract of Rabbit brain with buffer, stabilisers and calcium chloride. n Lyophilised reagents n Stable for 5 days at 2-8C n Expected range: 12 to 19 secs TEClot FIB TEClot FIB is intended for the quantitative determination of fibrinogen in human plasma according to the method developed by Clauss. Levels of fibrinogen can increase as a result of inflammation, pregnancy or oral contraceptive use. Decreased levels can be found in certain states such as liver disease and Disseminated Intravascular Coagulation (DIC). Congenital deficiencies include afibrinogenaemia (no detectable fibrinogen), hypofibrinogenaemia (<1 mg/ml) and dysfibrinogenaemia (abnormal fibrinogen molecule). n Bovine thrombin approximately 80 NIH units/ml n Reconstituted reagent stable for 8 hours at ambient temperature TEClot APTT-S TEClot TT reagent can be used manually or on semi-automated and automated instruments. The test is commonly applied to detect various sources of interference with normal blood coagulation. Prolongation of the thrombin clotting time can be taken as a qualitative indication of abnormal fibrinogen levels (high or low), or the presence of interfering substances such as FDP’s or heparin. n Lyophilised bovine thrombin n Final working concentration of Bovine thrombin 3NIH units/ml n Reconstituted reagent stable for up to 8 hours at ambient temperature Looking for Controls? – see pages 299-301 TEClot PT-S Catalogue Number Description Pack Size A0230-040 PT-S Reagent 10 x 4ml TECO Medical TEClot PTT-S Catalogue Number Description Pack Size A0320-100 APTT-S Reagent 10 x 10ml TECO Medical TEClot FIB Catalogue Number Description Pack Size A0500-010 Thrombin Reagent IBS Buffer TECal Normal TEControl A 5 x 2ml 1 x 125ml 1 x 1ml 1 x 1ml TECO Medical TEClot TT Catalogue Number Description Pack Size A0400-010 TT Reagent 5 x 2ml TECO Medical Haemostasis Routine Screening Reagents


Catalogue_WEB_WoP_Jun16
To see the actual publication please follow the link above