Page 254

Catalogue_WEB_WoP_Jun16

Clinical Chemistry HbA1c Controls A1c-Cellular® Streck’s A1c-Cellular is a whole blood cellular control for HbA1c and is the only A1c control on the market with intact red blood cells. A1c-Cellular tests the entire HbA1c performance, including the lysing of the red blood cell - a step omitted with other controls. This important step ensures the entire system, instrument and reagents, is working properly and providing accurate patient results. Pricing and Online Ordering at www.alphalabs.co.uk n freephone order 0800 387732 n buy online at www.alphalabs.co.uk 252 n Ready to use liquid control n Open-vial stability of 30 days n Closed-vial stability of 6 months Technical information: A1c-Cellular is available in cap-pierceable plastic vials, which allows autosampling for HbA1c analysers with such capabilities. It is appropriate for immunoassay and ionic exchange HPLC methodologies and is assayed for: ■■ Abbott ARCHITECT® c Systems ■■ ARKRAY Menarini ADAMS™ A1c HA-8160 ■■ Beckman Coulter® Synchron® Systems, UniCel® DxC Systems ■■ Bio-Rad® D-10, Variant II™, Variant II™ Turbo ■■ Siemens Dimension™ Series ■■Ortho-Clinical Diagnostics VITROS® 5,1 FS; VITROS® 5600 ■■ Roche Diagnostics Cobas INTEGRA®, Cobas® 6000 ■■ Tosoh G7, G8, A1c 2.2 Plus A1c-Cellular is available in two clinically significant levels: A1c Cellular Control Catalogue Number Description Pack Size 211130 A1c-Cellular - Levels 1 & 2 2 x 2.0ml 211124 A1c-Cellular - Levels 1 & 2 6 x 2.0ml Streck A1c-Cellular® Linearity Streck’s A1c-Cellular Linearity evaluates the accuracy and precision of HbA1c procedures over instrument reportable range. A1c-Cellular Linearity is a 5-level assayed linearity material used to assess instrument accuracy and verify the reportable range of the Haemoglobin A1c (HbA1c) parameter. It is the only commercially-available linearity/ calibration verification material containing intact red blood cells. It tests the entire reportable range of the instrument for bias, including the lyse step. n Ready to use liquid control n Open-vial stability of 7 days n Closed-vial stability of 105 days Technical information: A1c-Cellular Linearity is available in cap-pierceable plastic vials, which allows autosampling for HbA1c analysers with such capabilities. Vials also include barcodes. Instrument specific target values and expected ranges are provided for immediate instrument accuracy verification. Assayed Instruments: ■■ Beckman Coulter® Synchron CX®/LX® &, UniCel® DxC 600/800 Synchron® ■■ Bio-Rad® Variant II™, Variant II™ Turbo & D-10™ ■■Ortho-Clinical Diagnostics VITROS® 5,1 FS & VITROS® 5600 ■■ Roche COBAS Integra®, Cobas® 6000 ■■ Siemens Dimension™ Series ■■ Tosoh G7, G8A A1c Cellular Control Catalogue Number Description Pack Size 285536 A1c-Cellular Linearity 5 level control 5 x 2.0ml Streck Assay Mean Level 1 2 - 5% HbA1c 20 - 53 mmol/mol Level 2 7 - 12% HbA1c 75 - 119 mmol/mol Typical ranges for A1c-Cellular Linearity Level 1 0% - 2% Level 2 4% - 7% Level 3 9% - 12% Level 4 14% - 16% Level 5 17% - 21% Clinical Chemistry HbA1c Controls


Catalogue_WEB_WoP_Jun16
To see the actual publication please follow the link above