Page 224

Catalogue_WEB_WoP_Jun16

Clinical Chemistry Acid Phosphatase Kinetic determination of total acid phosphatase (ACP) and non-prostatic ACP (ACP-NPP) in serum. Activity of total ACP increases in cases of Paget’s disease, hyperparathyroidism, bone cancer, Gaucher’s disease, Niemann-Pick disease and myelocytic leukemia. Prostatic ACP concentrations increase in cases of prostate cancer. Pricing and Online Ordering at www.alphalabs.co.uk n freephone order 0800 387732 n buy online at www.alphalabs.co.uk 222 n Dual reconstituted reagent n Linearity: up to 75U/L n Reconstituted reagent stability: 7 days when stored at 2-8C Technical information: Acid Phosphatase catalyses the hydrolysis, in acid medium, of 1- naphtylphosphate (1-NP) into 1-naphtol and phosphate. 1-naphtol reacts with diazo-2-chloro-5-toluene (Fast Red TR salt), forming an azo dye compound which absorbance increase is proportional to the total acid phosphatase activity (ACP). Prostatic acid phosphatase (ACP-P) is inhibited by tartrate and is detected with an indirect method by subtraction between ACP and non-prostatic acid phospatase (ACP-NPP). Acid Phosphatase Catalogue Number Description Pack Size 17617 Acid Phosphatase Assay Reagent 6x20;1x3ml 16550 Clin Chem Calibrator 4x3ml 16150 Clin Chem Control 1 6x5ml 16250 Clin Chem Control 1 6x5ml Sentinel Alanine Aminotransferase (ALT) Kinetic determination of ALT according to IFCC recommendations in serum and plasma. ALT and Aspartate Aminotransferase (AST) are enzymes that catalyse the conversion of -keto acids into amino acids by transfer of amino groups. ALT is a specific liver enzyme and an indicator of hepatobiliary diseases. n Dual liquid-stable reagent n Linearity: up to 300 U/L n On-board stability is typically 30 days Technical information: Alanine Aminotranferase (ALT) catalyses the reaction of transamination between -ketoglutaric acid and L-alanine, with formation of L-glutamic acid and pyruvic acid. The formed pyruvic acid, in presence of lactate dehydrogenase (LDH), reacts with ß-NADH2 by forming lactic acid and ß-NAD in the same quantity. By measuring the variation of absorbance caused by ß- NAD in an interval of time, the enzyme activity in the sample can be calculated. Alanine Aminotransferase (ALT) Catalogue Number Description Pack Size 17234H ALT UV Liquid 2x65ml;1x19ml 16550 Clin Chem Calibrator 4x3ml 16150 Clin Chem Control 1 6x5ml 16250 Clin Chem Control 1 6x5ml Sentinel Albumin (Colorimetric) For the direct colorimetric determination of albumin in serum or plasma. Albumin is one of the most important carrier and binding proteins for various substances in plasma, and is also responsible for maintaining the osmotic pressure. Measurement of albumin is useful for the diagnosis of liver diseases such as cirrhosis and for monitoring nutritional status. n Single liquid-stable reagent n Linearity: up to 7000 mg/dL n On-board stability is typically 30 days Technical information: Albumin at pH 3.8 reacts with bromocresol green (BCG) forming a green coloured complex. The colour intensity of this complex is proportional to the concentration of albumin present in the sample. Albumin (Colorimetric) Catalogue Number Description Pack Size 17600H Albumin Colorimetric Assay 6x65ml 16550 Clin Chem Calibrator 4x3ml 16150 Clin Chem Control 1 6x5ml 16250 Clin Chem Control 1 6x5ml Sentinel Albumin (Turbidimetric) For the quantitative immunoturbidimetric determination of albumin in serum or plasma and microalbumin in urine. Albumin is one of the most important carrier and binding proteins for various substances in plasma and is also responsible for maintaining osmotic pressure. Measurement of albumin is useful for the diagnosis of liver diseases such as cirrhosis and to monitor nutritional and general health status. Albumin determination in urine is useful in the diagnosis of microalbuminuria (glomerular, tubular or post-renal) and as a marker protein for various forms of proteinuria. n Dual buffer with antibody preparation n Measuring range: 0.4-500mg/dl in urine n On-board stability is typically 21 days Technical information: The determination is based on a turbidimetric reaction between a specific polyclonal antiserum and albumin in the presence of polyethylenglycol polymer (PEG). The change in absorbance caused by the immuno-complex is proportional to the concentration of the analyte in the sample. Albumin (Turbidimetric) Catalogue Number Description Pack Size 11003N Albumin Turbidimetric Assay (Urine) 1x66ml;1x1ml 11200D Plasmaproteins Calibrator 3x1ml 11207A Microalbumin Calibrator Urine 4x1ml 11211A Immuno Control Set (2 Levels) 2x(2x1)ml 125001 Microalbumin Control (2 Levels) 2x(5x7)ml Sentinel Clinical Chemistry - A


Catalogue_WEB_WoP_Jun16
To see the actual publication please follow the link above